#Wait for a while with a timer event
An intermediate timer event holds the process for a fixed number of days, hours, minutes and seconds, and then lets it continue — also across a restart of Chester.
#What happens when the process reaches it
flowchart LR
A["Send reminder"] --> T(("Timer<br/>2 days"))
T -- "the time is up" --> B["Check the reply"]
R["Chester restarts<br/>during the wait"] -. "keeps the due time" .-> T
When the process arrives, Chester works out the time the wait ends — now plus the duration — and keeps it. When that time comes, the process moves on. If Chester is not running at that moment, the process moves on as soon as it is back; the downtime does not add to the wait.
#Configure a timer
- Select the timer event and open Timer configuration.
- In Timer Offset, click the field and set Days, Hrs., Min. and Sec.
The line below shows the value that is stored, in ISO 8601 — for example
P2Dfor two days,PT30Mfor half an hour.
The field is required. It takes numbers only.
#Wait for whichever comes first
To wait for a reply or give up after a while, put the timer behind an event-based gateway next to a message catch event. The path whose event happens first is taken; the other one is withdrawn. See Gateways.
This is also the only way to put a time limit on waiting: a timer boundary event on a task is not available.
#What the timer hands on
Nothing. A timer adds no data to the process.
#What a timer event cannot do
- ❌ Wait until a date or time of day. Only a duration is offered. A timer that has a date or a cycle instead — for example from a diagram made elsewhere — cannot be deployed.
- ❌ Repeat. There is no cycle.
- ❌ Use a duration from the process data. The duration is fixed in the diagram; an expression is not possible.
- ❌ Time out a task. Timer boundary events cannot be deployed. Use an event-based gateway instead, as above.
- ⚠️ Weeks, months and years. Only days, hours, minutes and seconds work. A value such as
P1WorP1Mtyped into a diagram gets only a warning, deploys, and then fails when the process reaches the timer. - ⚠️ Waits longer than about 24 days. A timer set to more than roughly 24.8 days does not wait: it fires almost immediately. Keep waits below three weeks, or chain several timers.
- ⚠️ A duration of zero lets the process continue at once.
#What validation checks
- A timer needs a duration: without one it gets the error that no duration is configured.
- A duration that does not look like ISO 8601 gets a warning only.
The messages are shown in German. See Check that a process can run.
